Component name

The 'Component name' command is used to modify the name of an existing component on a drawing. The 'Component name' command opens the 'Component name' menu, from which you can select the desired modification command.

 

Here you can change, delete or move the name; rotate it 90°; enlarge or reduce its size; or offset it from the cursor position. After selecting the desired modification command, from the 'Component name' menu, identify the specific component you wish to modify, using the left mouse button (or <Enter> key).

 

If you are modifying the name, the existing name appears in the prompt field, at the bottom of the screen, ready for modification. After making the required changes, accept them with the left mouse button (or <Enter> key) and then position the text as re­quired.

Hint

Remember that if you wish the name to be invisible in the drawing, place a '!' in front of it. The name remains visible until it has been positioned.

You can easily exclude  components from the material list

If the first sign (or the second one, if the name begins with '!') is a certain character, the component is not included in the material list. You can set this sign in the settings for the mate­rial list.

Tip

The parts in the libraries have names that are generally valid (e.g. NO 1 pole). These names also appear in the material list (except if you are working with the Mega module which uses information from the database). Therefore it is a good idea to give parts, that are often used in a library, appropriate names.