With this
command, the page number with the coordinates of the extended line which
has the same line name and is also open is written automatically at
open line ends (with connecting lines only). When using the destination
wiring elements for producing lines, another connection
designation must be entered as well as the line name. The cross
references are then created for lines with the same line
names and connection designation only.
Hint
The criterion for connecting open line ends is that the line names are the same.
The line ends are labelled in the direction of the line. With lines which are open on the right (or below or above), the automatic system searches on the following pages first but with lines which are open on the left, the automatic system searches on the preceding pages first. Open line ends can have different line names, even though they are at the same potential. This enables the cross references to be unambiguous.
Hint
Only line ends to which the same line name can be assigned refer to one another.
The beginning of the name must lie on the line between the end of the line and the next coordinate point of the line (kink or other line end), otherwise another appropriate name will be assigned for this line group. If several of such names are assigned for the group of lines, the first which is found in the drawing memory will be used.
Position the line name with active offset directly on the connection line, and the system and location identifications (SLI) will be placed in front if the destination has a different system and/or local identification. Some line cross references can be locked.
Hint
The current page must have an SLI, otherwise all cross-references are written without an SLI.
After entering the line name and connection name in the dialog, the on-line cross reference relating to the line is written if there are exactly TWO connection segments and the line name also has a connection name.
If a line has two open ends, the cross reference is written at the end, where the line name AND connection name agrees with the values just entered.
The function can be locked in the cross-references configuration and is not available in the Basic Version.
Hint
A connection segment is a symbol connection with an open line end, otherwise the symbol is connected nowhere. If several symbols are connected on the page, destination connection elements with 3 connection points must be used.
The function can be activated in the cross-reference configuration. In addition to the previous cross-reference text, the reference name and connection of the attached symbol can be entered on the extension page. In order to do so, a destination connection arrow need only be positioned ACCURATELY at the line end. The function text destination connection arrow must not be empty but can contain any text desired.
Hint
Exactly 2 connection segments must exist.
The display options of the destination module are set in the cross-references configuration:
· Without destination module, display of the cross reference as before.
· Single line, cross reference as before, then separators, then reference name: connection.
· 2-line, cross reference at previous position, reference name: connection one line below.