PLC + Main/side element

PLC + Main/side element. The distance between the lines is determined by the current Snap range. The cross-reference on Main and side elements is nor­mally written right-justified under the reference name, if the allocator ‘ws-q is not present in the component.  If several side elements are present, the cross-references are arranged below each other starting at the allocator.

 

With Main/side elements the allocator can also have trailing numerals.  These numerals can be used to differentiate between the individual side elements, provided these are also clearly numbered.  The numbers must begin with 1 and be continuous.  The cross reference is then written in the relevant position on the main element.

 

Example

!#lws-q1>

!#lws-q2>

Hint

The cross-references on side elements are not created On-line but only when the command is activated

At the same time the cross-references on PLC modules are newly created.  In the case of these components which are con­trolled by the PLC-manager, the position of the cross-references is always indicated by an associated allocator.

Hint

When the PLC manager is activated, these components are created On-line